Schneider Conext Automatic Generator start ( AGS)

SKU
SSEACC00007
AED582.00

*Price mentioned here as per Ex. w/h, Jebel Ali, Dubai and exclusive of shipping cost. We will update you the shipping cost as we proceed with your order.

Description:

The Conext™ Automatic Generator Start (AGS) can automatically activate or stop a generator in response to changing power requirements. Excellent addition to an off-grid or backup power system, the AGS seamlessly connects to the Xanbus network and shares status information with all other devices on the network. It can monitor a set of system user-programmable parameters such as battery voltage, state of charge or grid power and can activate the generator in response to any changes. The Conext™ AGS can also be configured remotely using the Conext™ System Control Panel (SCP) or insid energy management system to engage a generator and can assist an inverter/charger when output power demands are high.

Delivery Time:

2 to 4 weeks

The Conext™ Automatic Generator Start (AGS) can automatically activate or stop a generator in response to changing power requirements. Excellent addition to an off-grid or backup power system, the AGS seamlessly connects to the Xanbus network and shares status information with all other devices on the network. It can monitor a set of system user-programmable parameters such as battery voltage, state of charge or grid power and can activate the generator in response to any changes. The Conext™ AGS can also be configured remotely using the Conext™ System Control Panel (SCP) or insid energy management system to engage a generator and can assist an inverter/charger when output power demands are high.

Device short name Conext™ Automatic Generator Start
Electrical specifications
Nominal input network voltage 15 Vdc
Max. operating current 200 mA @ nominal input network voltage
Relay contact voltage rating 12 Vdc, 30 Vdc max1
Max. relay contact current 5 A DC1
Nominal 12/24 V thermostat input voltage 12 Vdc/24 Vdc1
= On
Min. 12/24 V thermostat input voltage 9.5 Vdc1
Max. 12/24 V thermostat input voltage 30 Vdc1
Typical 12/24 V thermostat input current 14.6 mA @ 12 V
Nominal 12/24 V generator running
B+ voltage 12 Vdc/24 Vdc1
= On
Min. 12/24 V generator running B+ voltage 9.5 Vdc1
Max. 12/24 V generator running B+ voltage 30 Vdc1
Typical 12/24 V generator running
B+ voltage 14.6 mA @ 12 V
General specifications
Dimensions (H x W x D) 9.55 x 14.6 x 3.7 cm (3.8 x 5.7 x 1.5 in)
Weight 225.0 g (0.5 lb)
Mounting options Wall-mount
IP rating/location IP20, indoor only
Warranty Please refer to our website, SEsolar.com for the latest version of the warranty statement.
Part number 865-1060-01
Communication
Network protocol Xanbus
Connectors 2 x RJ45 ports
Regulatory approvals
Safety CSA 107.1-01, UL 458 4th edition including the Marine supplement
EMC FCC part 15B Class B, Industry Canada ICES-0003 Class B, C-Tick
Included parts
One network terminator
One CAT5 cable (2.1 m)
One mounting plate
Four #6 screws
Compatible products part numbers
Conext XW Pro UL(120/240 V) XW Pro 6848 NA: 865-6848-21
Conext XW+ IEC (230 V) XW+ 8548 E: 865-8548-61
Conext XW+ UL (120/240 V) XW+ 6848 NA: 865-6848-01
Conext SW IEC (230 V) SW 4024: 865-4024-55 / SW 4048: 865-4048-55
Conext SW UL (120 V) SW 4024: 865-4024-21 / SW 4048: 865-4048-21
Conext MPPT 80 600 865-1032
Conext MPPT 60 150 865-1030-01
Conext Gateway 865-0329
Conext System Control Panel 865-1050-01
Conext Battery Monitor 865-1080-01
Conext Configuration Tool 865-1155-01

Higher return on investment
• Integrate with an inverter/charger to maximize system power performance Designed for reliability
• Tested and qualified for harsh environmental conditions (HALT reliability testing)

Flexible
• Works with multiple Xanbus devices: Conext™ XW Pro, XW+, SW, MPPT 60-150, MPPT 80-600, SCP and Gateway
• User-programmable trigger settings to meet specific application needs: – Battery voltage – SOC – Exercise time
– Quiet time – Inverter/charger AC power loads
• Supports manual start and stop operation modes

Easy to service
• Access and troubleshoot AGS device events using the Conext™ Gateway or SCP
• Easily upgrade new firmware to the AGS using the Conext™ Gateway

Easy to install
• Wall mount
• RJ45 connections for Xanbus network cables True bankability
• Warranty from a trusted partner with 180 years of experience
• World leader in industrial power drives, UPS and electrical distribution
• Strong service infrastructure worldwide to support your global needs