Sungrow 250HX Multi-MPPT String Inverter for 1500 Vdc System

SKU
SGRINV250-HX
AED29,662.98

*Price mentioned here as per Ex. w/h, Jebel Ali, Dubai and exclusive of shipping cost. We will update you the shipping cost as we proceed with your order.

Description:

String inverter, 20000Wac, 2 MPPT(4inputs per MPPT), maximum DC input voltage (Vmax,abs)- 1000V;

Product Tag: sungrow power, sungrow china, sungrow solar, solar inverter, solar inverter price, solar panel inverter, solar power inverter, hybrid solar inverter, solar inverter system

  • Power phase: Three Phase

Delivery Time:

2 to 4 weeks

Sungrow 250HX Multi-MPPT String Inverter for 1500 Vdc System, HIGH YIELD - 12 MPPTs with max. efficiency 99%,Compatible with bifacial module

  • Compatible with Al and Cu AC cables
  • DC 2 in 1 connection enabled
  • Power line communication (PLC)
  • Q at night function
  • Touch free commissioning and remote firmware upgrade
  • Online IV curve scan and diagnosis*
  • Fuse free design with smart string current monitoring
  • IP66 and C5 protection
  • Type II SPD for both DC and AC
  • Compliant with global safety and grid code

 

Product Tag: sungrow power, sungrow china, sungrow solar, solar inverter, solar inverter price, solar panel inverter, solar power inverter, hybrid solar inverter, solar inverter system

 

Dimensions (W*H*D): 1051 * 660 * 363 mm

Weight: 95kg

Isolation method: Transformerless

Ingress protection rating: IP66

Night power consumption: < 2 W

Operating ambient temperature range: -30 to 60 ℃

Allowable relative humidity range (non-condensing): 0 – 100 %

Cooling method: Smart forced air cooling

Max. operating altitude: 4000 m (> 3000 m derating)

Display: LED, Bluetooth+APP

Communication:  RS485 / PLC

DC connection type: Amphenol UTX (Max. 6 mm² )

AC connection type: OT terminal (Max. 300 mm²)

Compliance: IEC 62109, IEC 61727, IEC 62116, IEC 60068, IEC 61683, VDE-AR-N 4110:2018, VDE-AR-N 4120:2018, IEC 61000-6-3, EN 50549, UNE
206007-1:2013, P.O.12.3, UTE C15-712-1:2013

Grid Support: Q at night function, LVRT, HVRT,active & reactive power control
and power ramp rate control

True three-phase bridge topology for DC/AC output converter


Transformerless topology


Each inverter is set on specific grid codes which can be selected in the field


Detachable wiring box to allow an easy installation

Wide input voltage range


Integrated string combiner with different options of configuration which include DC and AC disconnect switch in compliance with international standards (S2, S1J, -S2J, -S2F and-S2X versions)

Natural convection cooling for maximum reliability


Outdoor enclosure for unrestricted use under any environmental conditions


Capability to connect external sensors for monitoring environmental conditions


Availability of auxiliary DC output voltage (24 V, 300 mA)