DEIF ASC – 4 Battery Controller

SKU
DMEACC00002
AED17,195.56

*Price mentioned here as per Ex. w/h, Jebel Ali, Dubai and exclusive of shipping cost. We will update you the shipping cost as we proceed with your order.

Description:

Designed specifically to serve as a reliable, fully integrated and optimising link between sustainable power plants and genset power plants, DEIF’s automatic sustainable controller, ASC-4 Battery, offers seamless energy storage integration in hybrid microgrid applications.

Product Tags: DEIF, Fuel Save Controller, Battery Controller

  • Product Type: Fuel Save Controller

Delivery Time:

2 to 4 weeks

Designed specifically to serve as a reliable, fully integrated and optimising link between sustainable power plants and genset power plants, DEIF’s automatic sustainable controller, ASC-4 Battery, offers seamless energy storage integration in hybrid microgrid applications.
ASC-4 Battery is ideal for both AC- and DC-coupled applicationsF
The ASC-4 Battery handles applications that use battery power as the primary power source (instead of gensets) as well as applications that use battery power for short-term support (for instance to support gensets for a short period of time) equally well.

Product Tags: DEIF, Fuel Save Controller, Battery Controller

Accuracy

Class 1.0
-25 to 15 to 30 to 70 °C
Temperature coefficient: ±0.2 % of full scale per 10 °C
Class 0.5 with option Q1
Positive, negative and zero sequence alarms: Class 1 within 5 % voltage unbalance
Class 1.0 for negative sequence current
Fast over-current: 3 % of 350 %*In
Analogue outputs: Class 1.0 according to total range

Operating temperature
-25 to 70 °C (-13 to 158 °F)
-25 to 60 °C (-13 to 140 °F) if Modbus TCP/IP (option N) is available in the controller
(UL/cUL Listed: Max. surrounding air temperature: 55 °C/131 °F)
Storage temperature -40 to 70 °C (-40 to 158 °F)
Climate 97 % RH to IEC 60068-2-30

Operating altitude
0 to 4000 m above sea level
Derating 2001 to 4000 m above sea level:
Max. 480 V AC phase-phase 3W4 measuring voltage
Max. 690 V AC phase-phase 3W3 measuring voltage

Measuring voltage
100 to 690 V AC ±20 %
(UL/cUL Listed: 600 V AC phase-phase)
Consumption: Max. 0.25 VA/phase

Measuring current
-/1 or -/5 A AC
(UL/cUL Listed: from CTs 1 to 5 A)
Consumption: Max. 0.3 VA/phase
Current overload
4 × In continuously
20 × In, 10 sec (max. 75 A)
80 × In, 1 sec (max. 300 A)

Measuring frequency 30 to 70 Hz

Automatic shift between grid forming/following operation
Charging/discharging
Power Conversion System (PCS) control
Batter Management System (BMS) monitoring
Control of breaker
Simple graphical configuration
Record time commissioning with DEIF Emulation
uses and verifies the functions of the real system for test, production and design
Suitable for power management solutions fitted with AGC-4 or AGC 200 genset controllers
Suitable for stand-alone solutions using multi-instruments such as DEIF’s MIB or MIC